Air velocity test and air changes rates calculation, Air Balancing, Pressure Balancing
Available all the latest equipment’s for air flow quality testing eg. Hot wire Anemometer, Vane type Anemometer or capture hood (Accubalancer) with national/ International traceable certificates.
HEPA Filter Leak Integrity Test [PAO or DOP]
Providing latest photometer for HEPA filters leak integrity. To validate integrity of a filtration system , a known challenge agent consist of an air born test aerosol is generated and introduce upstream of the filter. The challenge agent provides particulate matter upstream of the filter to allow measurement downstream of the filter.
Hot DOP/PAO test as well as Printing facility with Photometer are aslo available now.
Particle Count Test
Non-Viable Particle Count Test
Providing the complete range of particle counting as per new guideline ISO 14644 – 1,2,3: 2015. Providing the complete range of capacity of Particle counters eg. 1 CFM, 50 LPM, 100 LPM
Recovery Test
Execute recovery tests for clients across Industries. These tests demonstrate the ability of the clean room to remove particulate by purging the area with filtered air. It also testifies if the room can change from a “dirty” to “clean” state within the specified time. The test is conducted by experienced technicians from team. Our technicians have enriching experience and provide clients with high quality service. The ultimate goal of our company is to assure complete satisfaction of clients through effective execution of services and by providing best array of clean room equipment. We ensure that client’s clean room facility is performing properly and accurately
Air Flow Pattern
Safe zone defining test of RLAF and LAF
Offer Airflow Visualization Test as a part of the validation process. We are using DI water foggers as well as Glycerin foggers. Air flow pattern is carried out by using water fogger and taking Video Graph. The purpose of the airflow visualization test is to show the actual airflow pattern throughout the unidirectional clean room. The test can also be used to demonstrate the effects on airflow caused by equipment. It is best to perform this test after all airflow velocity and uniformity tests and room pressurization tests have been performed. The test determining the airflow patterns within a room using ISO 14644 guides.
Also DI Water fogger is now available
TEMPERATURE & HUMIDITY MAPPING / TESTING
Having total facility to measurement of temperature & RH for clean room as well as clean rooms equipment
Light Intensity Testing
Providing the facility of light intensity test. To calculate the light level in clean rooms which are uniformly meets to specified requirement.
Noise Level Measurement
Providing the facility of noise level test. To calculate the noice level in clean rooms which are uniformly meets to specified requirement.